Production information
Standard Features
- 1/60,000 displayed Resolution, A/D conversion 120 time/sec.
- Power for eight 350Ω load cells.
- 100 codes: Final / SP1 / SP2 / FF / HI / LO.
- Automatic Free Fall Compensation.
- Input: Zero, Tare, Tare Clear, Start, Stop, Print Accumulation, Print, Clear Count.
- Output: Zero band, SP1, SP2, (Final-Finish), HI, LO, Final, Unstable/Error.
- Standard: OP-01 Control I/O and 20mA Current Loop for BDI-9910.
As a weighbridge manufacturing company, we are dedicated to providing reliable and precise weighing solutions tailored to your needs.
| Options | ||
| OP-01 Control I/O | ||
| OP-02 RS-232 / 422 / 485 | ||
| OP-03 Printer Interface | ||
| OP-04 BCD | ||
| OP-05 Analog 4-20mA | ||
| OP-06 Analog 0-10V | ||
| OP-07 Remote Ser Point Unit:Final Weight | ||
| OP-08 RELAY control interface |
General
| Type | BDI-2002 |
| Power Requirements | AC 110V or AC 220V±10%, 50 / 60Hz, Approx. 17VA |
| Net weight | Approx. 3.2kg【7.054lb】 |
| Operation Temperature | -10 ~ 45℃ |
| Maximum Humidity | 85%【Non-condensing】 |
| Physical Dimensions | 248 × 190 × 104mm (D × W × H) |
Analog Input and A/D Conversion
| Type | BDI-2002 |
| Input Sensitivity | ≧0.3μ V/D |
| ZERO Adjustment Range | 0~20mV |
| Laod Cell Excitations | DC 10V±1%, 230mA, Remote Sensing. Can be connected up to 8 350Ω Load Cells. |
| Non-Linearity | 0.001%F.S. |
| A/D Conversion Method | ΔΣ |
| A/D Resolution | ≒1/1,000,000 |
| A/D Conversion Rate | Approx. 120 Times / Sec. |
| Max. Loac Cell Input Voltage | 32mV |
| ZERO Temperature Comp | ± (0.2μ V+0.001% of Dead Load) / ℃ typ |
| SAPN Temperature Comp | ±0.001% ℃ typ |
| Max. Resolution | 1/16,000 (May reach 1/60,000 depending on load cell quality) |