BDI-2006 Weighing Indicator & Controller

Type:BDI-2006
3 Column Display: Code/Final/Weight.
A/D 120 times/sec. Max. Div. 1/60,000.
100 Material codes Filling or Batch Mixing.
High Speed Weighing Controller.
Built in Control I/O.

Production information

Standard Features

  • 1/16,000 displayed resolution (Max 1/60,000 depending on load cell quality & performace). Internal Resolution 1,000,000,A/D Conversion rate 120 times/ Sec.
  • Watchdog virtually eliminates malfunctions that associated with computerized equipment or software failure.
  • Full Digital Calibration makes setting ZERO and SPAN Calibration an easy task.
  • Drines up to 8 parallel connecting load cells.
  • 8k bytes SRAM with Lo-battery backup. Information will not disappear even power failure.
  • The settings of function and weighing parameters are all stored in the EEPROM,with storage duration over 40 years.
  • Important values and parameters can have storage backup.
  • Users can adjust the intensity of digits f ilter to avoid mechanical vibrat ion thatcaused by external environments to achieve high-speed and accuratemeasurement.
  • Set point codes can store up to 100 sets of : Final, SP1, SP2, Free Fall, HI, LO.
  • Automatic Free Fall Compensat ion provides closer tolerance and preciseweighing.
  • 8 Set of control Input: ZERO Input, TARE Input, Tare reset, Startbatch,Abort batch, Print Accumulator, Print Input, Clear, ACC. &COUNT.
  • 8 Set of control Output:ZERO Band output, SP1 output, SP2 Output, (Final-FreeFall) output, HI output, LO output, Final Output, MD/Error output.
  • Standard Serial Output (20mA Current Loop) for remote display.
  • Optional pr inter inter face can automatically print or output data includes: date,time, set point code, serial number, weight, and unit.
 
Options
OP-01 Control I/O
OP-02 RS-232 / 422 / 485
OP-03 Printer Interface
OP-04 BCD
OP-05 Analog 4-20mA
OP-06 Analog 0-10V
OP-07 Remote Set Point Unit:Final Weight
OP-08 RELAY Comtrol Interface

General

 
Type BDI-2006
Power Requirements AC 110V or AC 220±10%,50 / 60Hz, Approx. 17VA
Net weight Approx. 3.2kg【7.054lbs】
Operation Temperature -10℃ ~ 45℃
Maximum Humidity 85%【non-condensing】
Physical Dimensions 240 × 190 × 104mm (D × W × H)

Analog Input and A/D Conversion

 
Type BDI-2006
Input Sensitivity ≧0.3uV/D
ZERO Adjustment Range 0~20mV
Load Cell Excitation DC 10V±1%,230mA, Remote Sensing.
Cannected up to 8 350Ω Load Cells.
Non-Linearity 0.01% F.S.
A/D Conversion Method ΔΣ
A/D Resolution ≒1/1,000,000
A/D Conversion Rate Approx. 120Times/Sec.
Max. Load Cell Input Voltage 32mV
ZERO Temperature Comp ±(0.2uV+0.001% of Dead Load) / ℃ typ
SPAN Temperature Comp ± 0.001% ℃ typ
Max. Resolution 1/16,000 (BDI-2006 Resolution can reach 1/60,000 depending on load cell quality & performance)