Can a checkweigher detect one missing tablet in a bottle?
Bottle lines often ask us whether a checkweigher can reject a bottle with one tablet missing. The answer depends on three numbers, not on the bottle weight alone.
The three numbers that decide it
- The weight of one tablet: this is the difference you must detect.
- The weighing error of the checkweigher at your line speed.
- The weight spread of everything else in the bottle: the bottle, cap, liner, desiccant and label.
One missing tablet is only detectable when its weight is clearly larger than the weighing error plus the natural spread of the packaging. If the bottles themselves vary by about the weight of one tablet, weighing alone cannot separate a short bottle from a heavy empty bottle.
Our bottle checkweighers
| Series | Weighing range | Weighing error | Product size (L × W) |
|---|---|---|---|
| BCW80 | 2-50 g | from ±0.03 g | 70 × 150 mm |
| BCW120 | 10-300 g | from ±0.05 g | 100 × 250 mm |
| BCW160 | 20-3000 g | from ±0.1 g | 130 × 350 mm |
BCW weighs plastic or glass bottles standing up, stores 99 product settings and saves inspection records to a PC or USB drive as Excel files.
What to send us
- Tablet weight for each SKU
- Bottle weight range with and without desiccant
- Line speed in bottles per minute
- Bottle size and material
Frequently asked questions
Can one machine handle a 0.1 g tablet SKU and a 0.3 g tablet SKU?
One machine can store 99 product settings, but the smallest tablet decides the accuracy you need. Size the machine for the lightest tablet and the heaviest bottle on the line.
More weighing FAQ
Tell us what you weigh, the capacity, accuracy and where it will be used.