Language
  • 繁體中文
  • English
  • Español
  • ﻉﺮﺑﻯ
  • русский
0
Inquiry Cart List

Weighing indicator wiring: 4-wire and 6-wire load cells

A load cell has two excitation wires, two signal wires and usually a shield. Six-wire cells add two sense wires. Wiring them correctly to the weighing indicator is the first step to a stable reading.

What each wire does

TerminalFunction
EXC+ / EXC-Excitation voltage supplied by the indicator
SIG+ / SIG-Millivolt output from the load cell
SEN+ / SEN-Sense lines that measure the excitation voltage at the cell (6-wire)
ShieldDrain for electrical noise, grounded at one point

4-wire or 6-wire

Six-wire connection lets the indicator compensate for voltage drop along long cables and for cable temperature changes. With a 4-wire load cell on a 6-wire indicator, link SEN+ to EXC+ and SEN- to EXC- at the indicator terminal. Wire colors differ between brands, so always follow the load cell data sheet.

Several load cells

Connect each load cell to a junction box and run one cable to the indicator. The junction box is also where corner errors are trimmed. Check the indicator's limit on the number of load cells; BDI-9301B and BDI-2001B take up to 8.

Keep the signal clean

  • Route load cell cables away from motor, inverter and power cables.
  • Ground the shield at the indicator end only, to avoid ground loops.
  • Use sealed junction boxes outdoors and surge protection on weighbridges.

More weighing FAQ

Need a quote or help choosing a model?

Tell us what you weigh, the capacity, accuracy and where it will be used.